Elliott Industries, Inc.
Get Free Adobe Reader (to view .PDF files)

Power Distribution Products

Index Tab 100 — General Information top of page

Bulletin 100-002 dated 2015
Terms & Conditions


Bulletin 100-003 dated 2015
Cancellation Policy


Bulletin 100-004 dated 2015
Return Policy

Index Tab 200 — Technical Information top of page

Report 87-72 dated 2001
Tamper Resistance Test Report for Elliott Pad-Mounted Enclosures


Drawing 85-156 dated 2002
Latch Part Detail


Bulletin 200-1000 dated 2015
Thermal Shock Induced Failures of Cycloaliphatic Epoxy Apparatus Bushings

Index Tab 320 — Capacitor Control Sockets & Brackets top of page

Product Line has been discontinued.

Index Tab 325 — Capacitor Switch Junction Boxes & Wiring top of page

Product Line has been discontinued.

Index Tab 330 — Secondary Enclosures top of page

Bulletin 330-060 dated 2015
600 Volt Secondary Enclosure
Pad-Mounted Outdoor

Index Tab 340 — Secondary Bus Enclosures top of page

Bulletin 340-062 dated 2015
600 Volt Secondary Bus Enclosure
Pad-Mounted Outdoor


Bulletin 340-067 dated 2016
600 Volt Secondary Bus Enclosure with Current Transformers
Pad-Mounted Outdoor


Bulletin 345-067 dated 2016
600 Volt Secondary Bus Enclosure with Current Transformers
Wall-Mounted Outdoor

Index Tab 350 — Miscellaneous Secondary Equipment top of page

Bulletin 350-050 dated 2015
Instrument Transformer Junction box


Bulletin 350-100 dated 2015
Electronic Recloser Cable


Bulletin 350-200 dated 2015
Control House Relay Panel

Index Tab 360 — UNI-SAF Junction Boxes top of page

Product Line has been discontinued.

Index Tab 400 — Safefront Pad-Mounted Switchgear top of page

Bulletin 400-106 dated 2018
15 kV Safefront 200 Amp Phase Isolated Mini-Switch
Arc-Strangler NX® Fuses and Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 400-110 dated 2018
15 kV Safefront 200 Amp Source Isolated Mini-Switch
Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 400-114 dated 2018
15 kV Safefront 200 Amp Phase Isolated Mini-Switch
S&C Fuses
Pad-Mounted Outdoor


Bulletin 400-206 dated 2018
25 kV Safefront 200 Amp Phase Isolated Mini-Switch
Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 400-210 dated 2018
25 kV Safefront 200 Amp Source Isolated Mini-Switch
Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 400-310 dated 2018
35 kV Safefront 200 Amp Source Isolated Mini-Switch
Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 400-311 dated 2016
35 kV Safefront 200 Amp SuperWell Source Isolated Mini-Switch
Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor

Index Tab 450 — Safefront Cable Switching Stations top of page

Bulletin 450-110 dated 2018
15 kV Safefront 200 Amp Source Isolated Cable Switching Station
Pad-Mounted Outdoor


Bulletin 450-120 dated 2018
15 kV Safefront 200 Amp Source Isolated Cable Switching Station
Pad-Mounted Outdoor


Bulletin 450-122 dated 2018
15 kV Safefront 600 Amp and 1250 Amp Source Isolated Cable Terminating Station
Pad-Mounted Outdoor


Bulletin 450-210 dated 2018
25 kV Safefront 200 Amp Source Isolated Cable Switching Station
Pad-Mounted Outdoor


Bulletin 450-222 dated 2018
25 kV Safefront 600 Amp and 1250 Amp Source Isolated Cable Terminating Station
Pad-Mounted Outdoor


Bulletin 450-310 dated 2018
35 kV Safefront 200 Amp Source Isolated Cable Switching Station
Pad-Mounted Outdoor


Bulletin 450-311 dated 2016
35 kV Safefront 200 Amp SuperWell Source Isolated Cable Switching Station
Pad-Mounted Outdoor


Bulletin 450-322 dated 2018
35 kV Safefront 600 Amp and 1250 Amp Source Isolated Cable Terminating Station
Pad-Mounted Outdoor


Index Tab 500 — Safefront Primary Metering Stations top of page

Bulletin 500-102 dated 2018
15 kV Safefront 200 Amp Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-104 dated 2018
15 kV Safefront 600 Amp Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-202 dated 2018
25 kV Safefront 200 Amp Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-204 dated 2018
25 kV Safefront 600 Amp Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-302 dated 2018
35 kV Safefront 200 Amp Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-303 dated 2016
35 kV Safefront 200 Amp SuperWell Primary Metering Station
Pad-Mounted Outdoor


Bulletin 500-304 dated 2016
35 kV Safefront 600 Amp Primary Metering Station
Pad-Mounted Outdoor

Index Tab 540 — Safefront Distribution Transformer Stations top of page

Bulletin 540-102 dated 2018
15 kV Safefront 200 Amp Primary Transformer Station
Pad-Mounted Outdoor


Bulletin 540-104 dated 2018
15 kV Safefront 600 Amp Primary Transformer Station
Pad-Mounted Outdoor


Drawing 99-349-1,2,3 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 25 kVA Max
Pad-Mounted Outdoor


Drawing 99-350-1,2,3 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 25 kVA Max
Pad-Mounted Outdoor


Drawing 99-351-1,2,3 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 75 kVA Max
Pad-Mounted Outdoor


Drawing 99-352-1,2,3 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 75 kVA Max
Pad-Mounted Outdoor


Drawing 99-353-1,2,3,4 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 250 kVA Max
Pad-Mounted Outdoor


Drawing 99-354-1,2,3,4 dated 1999
25 kV Safefront 200 Amp Primary Transformer Station for three 250 kVA Max
Pad-Mounted Outdoor


Bulletin 540-206 dated 2015
Typical Specification - 25 kV Safefront 200 Amp Primary Transformer Station
Pad-Mounted Outdoor


Drawing 99-359-1,2,3 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 25 kVA Max
Pad-Mounted Outdoor


Drawing 99-360-1,2,3 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 25 kVA Max
Pad-Mounted Outdoor


Drawing 99-361-1,2,3 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 75 kVA Max
Pad-Mounted Outdoor


Drawing 99-362-1,2,3 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 75 kVA Max
Pad-Mounted Outdoor


Drawing 99-363-1,2,3,4 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 250 kVA Max
Pad-Mounted Outdoor


Drawing 99-364-1,2,3,4 dated 1999
25 kV Safefront 600 Amp Primary Transformer Station for three 250 kVA Max
Pad-Mounted Outdoor


Bulletin 540-208 dated 2015
Typical Specification - 25 kV Safefront 600 Amp Primary Transformer Station
Pad-Mounted Outdoor

Index Tab 550 — Wall-Mount Switchgear top of page

Drawing 94-248 dated 1994
15 kV Wall-Mount Fuse Gear
Code 5 Clip-Mounted Current-Limiting Fuses
200 Amp Bushings for Elbow Termination on Top and Bottom
Wall-Mounted Outdoor


Drawing 94-249 dated 1994
15 kV Wall-Mount Fuse Gear
Code 5 Clip-Mounted Current-Limiting Fuses
200 Amp Bushings for Elbow Termination on Front and Bottom
Wall-Mounted Outdoor


Drawing 94-250 dated 1994
15 kV Wall-Mount Fuse Gear
Code 5 Clip-Mounted Current-Limiting Fuses
200 Amp Bushings for Elbow Termination on Front
Wall-Mounted Outdoor


Bulletin 550-116 dated 2015
15 kV Wall-Mount Fuse Gear
200 Amp S&C SMU-20 or SM-4 Fuses
600 Amp Bushings for Elbow Termination
Wall-Mounted Indoor/Outdoor


Bulletin 550-126 dated 2015
15 kV Wall-Mount Switchgear
600 Amp S&C Mini-Rupter® Switch
600 Amp Bushings for Elbow Termination
Wall-Mounted Indoor/Outdoor


Bulletin 550-216 dated 2015
25 kV Wall-Mount Fuse Gear
200 Amp S&C SMU-20 or SM-4 Fuses
600 Amp Bushings for Elbow Termination
Wall-Mounted Indoor/Outdoor


Bulletin 550-226 dated 2015
25 kV Wall-Mount Switchgear
600 Amp S&C Mini-Rupter® Switch
600 Amp Bushings for Elbow Termination
Wall-Mounted Indoor/Outdoor

Index Tab 560 — Miscellaneous Safefront Equipment top of page

Bulletin 560-202 dated 2018
25 KV Safefront 200 Amp Ground Fault Sensing Station
Pad-Mounted Outdoor


Bulletin 590-102 dated 2015
15 KV Safefront 200 Amp Primary Oil Switch Station
Pad-Mounted Outdoor

Index Tab 630 — Primary Enclosures top of page

Bulletin 630-060 dated 2015
Primary Equipment Enclosure
Pad-Mounted Outdoor

Index Tab 700 — Live Terminal Pad-Mounted Switchgear top of page

Bulletin 705-104 dated 2015
15 kV Live Terminal 200 Amp Mini-Switch, Phase Isolated Switchgear
40 Amp (Max) Arc-Strangler NX® Fuses
Pad-Mounted Outdoor


Bulletin 705-110 dated 2015
15 kV Live Terminal 200 Amp Mini-Switch, Source Isolated Switchgear
40 Amp (Max) Arc-Strangler NX® Fuses
Pad-Mounted Outdoor


Bulletin 730-122 dated 2009
15 kV Live Terminal 600 Amp Group Operated Mini-Switch Source Isolated Switchgear
200 Amp S&C SML-20 and SML-4Z Fuses
Pad-Mounted Outdoor

Index Tab 745 — Live Terminal Metal Enclosed Switchgear top of page

Bulletin 745-112 dated 2015
15 kV Live Terminal 600 Amp Group Operated Metal-Enclosed Switchgear
140 Amp (Max) Clip-Mounted Current-Limiting Fuses
Pad-Mounted Outdoor


Bulletin 745-114 dated 2015
15 kV Live Terminal 600 Amp Group Operated Metal-Enclosed Switchgear
200 Amp (Max) S&C SMU-20 and SM-4 Power Fuses
Pad-Mounted Outdoor


Drawing 92-49-1,2 dated 1992
15 kV Live Terminal 600 Amp Group Operated Metal-Enclosed Switchgear
400 Amp (Max) S&C SM-5S Power Fuses
Pad-Mounted Outdoor


Drawing 94-2-1,2,3,4 dated 1994
15 kV Live Terminal 600 Amp Group Operated Metal-Enclosed Switchgear
200 Amp (Max) S&C SM-4Z Power Fuses
Pad-Mounted Outdoor

Index Tab 760 — Live Terminal Cable Terminating Stations top of page

Bulletin 760-112 dated 2015
15 kV Live Terminal Cable Terminating Station, Three Phase
Pad-Mounted Outdoor


Bulletin 760-212 dated 2015
25 kV Live Terminal Cable Terminating Station, Three Phase
Pad-Mounted Outdoor


Bulletin 760-312 dated 2015
35 kV Live Terminal Cable Terminating Station, Three Phase
Pad-Mounted Outdoor

Index Tab 800 — Live Terminal Primary Metering Stations top of page

Bulletin 800-104 dated 2015
15 kV Live Terminal Primary Metering Station
Pad-Mounted Outdoor

Index Tab 820 — Live Terminal Primary Capacitor Stations top of page

Please contact the factory for
Live Terminal Primary Capacitor Station
designs at
sales@elliott-industries.com

Molding & Components Products

Index Tab 1000 — High Voltage Bushings top of page

Bulletin 1003-100 dated 2018
Cycloaliphatic Epoxy Bushings


Bulletin 1025-200 dated 2019
25 kV "B" Series Apparatus Bushings, Uni-Mount bolt in,
Elbow to Air-Insulated


Bulletin 1025-250 dated 2018
25 kV "B" Series Apparatus Bushings, Uni-Mount bolt in,
Elbow to Elbow


Bulletin 1035-200 dated 2019
35 kV "B" Series Apparatus Bushings, Uni-Mount bolt in,
Elbow to Air-Insulated


Bulletin 1035-250 dated 2018
35 kV "B" Series Apparatus Bushings, Uni-Mount bolt in,
Elbow to Elbow


Bulletin 1351 dated 2018
15 kV and 25 kV "B" Series Thru-Bushings, Uni-Mount bolt in,
Air-Insulated to Air-Insulated


Bulletin 1352 dated 2018
35 kV "F" Series Thru-Bushings, bolt in,
Air-Insulated to Air-Insulated

Index Tab 2000 — Insulators top of page

Bulletin 2003-100 dated 2019
Bulletin Selection Guide
Cycloaliphatic Epoxy Insulators


Bulletin 2101-001 dated 2015
Apparatus Insulators
Both Ends: One 0.375"-16 Insert


Bulletin 2101-005 dated 2015
Apparatus Insulators
Base: Two 0.3125"-18 Inserts on a 1.125" bolt circle
Top: Two 0.3125"-18 Inserts on a 1.125" bolt circle rotated
90 deg.


Bulletin 2101-010 dated 2015
Apparatus Insulators
Both Ends: One 0.5"-13 Insert


Bulletin 2111-001 dated 2015
Standard Duty Apparatus Insulators
Both Ends: Four 0.375"-16 Inserts on 2" bolt circle


Bulletin 2111-010 dated 2015
Standard Duty Apparatus Insulators
Base: Four 0.375"-16 Inserts on 2" bolt circle
Top: One 0.5"-13 Insert


Bulletin 2200-001 dated 2015
Heavy Duty Apparatus Insulators
Both Ends: Four 0.375"-16 Inserts on 2" bolt circle


Bulletin 2201-001 dated 2015
Apparatus Insulators
Special Bolt Series to accept S&C Live Parts


Bulletin 2350-001 dated 2015
Extra Heavy Duty Apparatus Insulators
Both Ends: Four 0.375"-16 Inserts on 2" bolt circle


Bulletin 2350-010 dated 2015
Extra Heavy Duty Apparatus Insulators
Base: Four 0.375"-16 Inserts on 2" bolt circle
Top: One 0.5"-13 Insert


Bulletin 2350-015 dated 2015
Extra Heavy Duty Apparatus Insulators
Both Ends: Four 0.375"-16 Inserts on 2" bolt circle
Top Center: One 0.5"-13 Insert


Bulletin 2375-001 dated 2015
Extra Heavy Duty Apparatus Insulators
Base: Four 0.5"-13 Inserts on 3" bolt circle
Top: Four 0.375"-16 Inserts on 2" bolt circle


Bulletin 2400-001 dated 2016
Station Post Insulators
Both Ends: Four 0.5"-13 Inserts on 3" bolt circle


Bulletin 2400-030 dated 2015
Extra Heavy Duty Apparatus Insulators
Base: Four 0.5"-13 Inserts on 3" bolt circle
Top: One 0.75"-10 Insert


Bulletin 2950 dated 2015
600 Volt Apparatus Insulator
Both Ends: Two 0.375"-16 Inserts


Bulletin 2960 dated 2015
600 Volt Apparatus Insulator
Both Ends: Two 0.50"-13 Inserts

Index Tab 3000 — Fuse Mountings top of page

Bulletin 3102 dated 2015
Single Fuse Clip-Style Fuse Mounting


Bulletin 3901 dated 2019
Fuse Extenders

Index Tab 5000 — Miscellaneous Molded Products top of page

Product Line has been discontinued.

Index Tab 6000 — Miscellaneous Special Products top of page

Product Line has been discontinued.

 
Elliott Industries, Inc.
1509 Hamilton Road · Bossier City, LA  71111  USA
Phone: 318-746-3296 · Fax: 318-741-1127
E-mail: sales@elliott-industries.com